Top Mounted Magnetic Flap Level Gauge

product details

Products

Top-mounted magnetic flip-plate level meter is a combination of basic type and tele-transmitter which can realize signal tele-transmission, liquid level alarm and control function.CH-UHZ type magnetic flip-plate level meter's intuitive, eye-catching, cost-effective, temperature-resistant, pressure-resistant, corrosion-resistant, explosion-proof features make it widely used in electric power, petroleum, chemical industry, metallurgy, environmental protection and other industries in the production process of liquid level measurement and automation control.


Top-mounted magnetic flip-plate level meter is a combination of basic type and tele-transmitter which can realize signal tele-transmission, liquid level alarm and control function.CH-UHZ type magnetic flip-plate level meter's intuitive, eye-catching, cost-effective, temperature-resistant, pressure-resistant, corrosion-resistant, explosion-proof features make it widely used in electric power, petroleum, chemical industry, metallurgy, environmental protection and other industries in the production process of liquid level measurement and automation control.

Product Features.

Suitable for liquid level and boundary level measurement of pressure vessels, it can integrate on-site indication, remote transmission and control alarm.

Novel indication, intuitive reading, eye-catching, according to the user's convenience to change the observation angle.

The measuring range is large and is not limited by the height of the storage tank.

The indication mechanism is fully isolated from the measured medium, thus it is well sealed, highly reliable and safe to use.

High-temperature resistant, can use colorless ceramic flip column.

Simple structure, easy installation, low maintenance



Technical parameters

1、Material of the body: 304, 316, 316L, PP plastic

2、Medium density: 0.49 ~ 1.99 (g/cm3)

3、Medium viscosity: ≤0.019Pa.S

4、Measuring accuracy: ±10mm

5、Protection grade: IP65

6、Explosion-proof grade: ibⅡCT4 (intrinsically safe), dⅡBT4 (explosion-proof)

7、Transmission mode: 4-20ma.



III. Product Selection


CH-UHZ Magnetic Flip-Flop Level Gauge
Code Display Mode

In-situ display

Local display + 4~20mA remote transmission

nicknames Installation
C side-mounted
D top-loading

nicknames typology
not have karyotype (chemistry)
W Insulation type
J Anti-corrosion type
S Frostproof
Z Thermal insulation and anti-corrosion type
Y Top-mounted corrosion-resistant type

nicknames Alarm control
0 no alarm
1 With upper limit alarm
2 With lower limit alarm
3 With lower limit alarm

nicknames Float Material nicknames Body Material
P stainless steels P stainless steels
L rustproof aluminum L rustproof aluminum
T titanium (chemistry) T titanium (chemistry)
S PVC plastic S PVC plastic
F fluoroplastic wrap F fluoroplastic pipe


PF Lined with PTFE


PP Acrylic lined


PE Vinyl lined

Code Data to be marked
B1 Marking flange standard, through diameter, pressure class
B2 Labeling of the actual operating temperature
B3 Labeling of actual operating pressure
B4 Labeling of the density of the measuring medium
B5 Mark order length, or provide flange spacing

IV. Selection specification

Top-mounted Magnetic Flap Level Gauge Side-mounted Magnetic Flap Level Gauge
顶装式磁翻板液位计 侧装式磁翻板液位计
Pseudolaric acid Magnetic Flip-Flop Level Gauge Measurement range 150-15000MM
Medium temperature -80℃~450℃ Medium Pressure 1.6-16MPA
Installation Side/top mounting (optional) Standard Flanges DN20/DN25(Optional)

Note: Selection should be based on the actual conditions to determine the site, different conditions selection is not the same, selection example: Model UHZ-C, side-mounted, medium alcohol, material 304, without display, with remote transmission, range 0 ~ 1500mm, temperature 180 ℃, flange DN25, (if the chemical industry, “must be”) (If it is a chemical enterprise, “must” be made into explosion-proof type)



Installation, use and maintenance

1, first check the level meter label data and ordering requirements are consistent with the distance from the level meter around the 200mm range shall not have the excitation of iron and other magnetic substances, otherwise it will affect the normal operation of the level meter.

2, the level meter and the container should be equipped with a shut-off valve between the maintenance and cleaning to cut off the material. The installation of the body must be vertical, *** offset angle ≤ 3 °. Measuring range > 4m in the process of installation and use should increase the intermediate support point.

3, the liquid level meter into operation, should first open the upper flange gas-phase valve, and then slowly open the lower flange liquid-phase valve, so that the medium slowly flow into the cylinder so that the flip column (plate) one by one tracking instructions, and adjust the zero level with the adjusting screw.

4、Level meter guard conduit and the main conduit must be kept vertical.

5、After the installation is completed, it is necessary to guide the flip column of the display with magnet once so that it shows red above zero level and white below zero level.