Radio Frequency Conductive Level Switches

product details

Products

CH-CPDN11 series RF conductive material level switch is a level measurement equipment for fly ash, solid particles and adherent materials with strong applicability and reliability based on absorbing the technical advantages of similar products at home and abroad and combining with the independent innovative technology and process of Keiwei.

  CH-CPDN11 series RF-conducting level switch realizes level measurement and control by sensing the change of reactance (capacitance and impedance) between the probe and the tank body. Its internal electronic unit, by the probe measuring pole and the reactance between the unloaded tank body together constitute a balanced bridge circuit and produce a stable oscillation signal. When the measured medium covers the probe measuring pole, it will cause changes in the reactance between the probe measuring pole and the tank, resulting in an imbalance of the bridge circuit and stop generating an oscillating signal, which is detected by the back-end circuit and thus outputs an alarm signal. The oscillating signal as a radio frequency signal applied to the probe measurement pole at the same time, but also through the 1:1 voltage follower sent to the probe's protection pole, measurement pole and the protection pole of the radio frequency signal with equal potential, the same phase, the same frequency and isolation from each other. When the probe has hanging material, the measuring pole and the protective pole because there is no potential difference and the formation of electrical isolation to ensure that the signal changes in the protective pole does not affect the detection, so that changes in reactance on the probe measuring pole can only be measured by the probe measuring pole and the material between the tank to determine the probe hanging material will not affect the normal detection.

  CH-CPDN11 series RF-conducting material level switch not only absorbs the design and technology of similar products at home and abroad, but also independently develops a series of innovative designs, production processes and testing standards, while focusing on the details of the process, strict control of the production process and quality inspection, to ensure that the product has a super-high reliability. The product has the following advantages over similar products of other brands:

  ● Strong applicability, widely used in the measurement of fly ash, solid particles and adherent materials;

  ● External dual-color LED indicator, and the meter head can be rotated relative to the process connection, by rotating the meter head to achieve LED orientation, convenient for remote observation;

  ● Modular design, high reliability, easy installation and maintenance;

  ● The product has passed the third-party reliability testing and certification, and has high reliability;

  ● High impact resistance, with stainless steel protective sleeve attached to the exterior;

  ● High temperature resistant design, process temperature up to 450℃.

  CH-CPDN11 series RFID level switches include four models: general-purpose, protective, cable, and ultra-high-temperature:

  CH-CPDN11A general-purpose RF-conductance material level switch: It is suitable for the measurement of dust, coal ash, etc. It has strong versatility and is easy to install and maintain.

  CH-CPDN11P Protective RF level switch: Based on the general-purpose type with stainless steel protection tube, it can withstand the impact of heavier materials.

  CH-CPDN11R cable type RF guided level switch: suitable for large tanks and silos, using vertical installation, effectively avoiding the side impact of materials.

  CH-CPDN11H Ultra-high-temperature RFID level switch: The probe is made of high-temperature resistant ceramic material, and the process temperature reaches 450℃.