Single Flange Differential Pressure Transmitter adopts fully sealed welded structure Diversified shape structure, high temperature resistant circuit board Sensor anti-interference, good long-term stability, lightning protection, anti-frequency interference, high precision, high stability, 316 stainless steel isolation diaphragm structure (or tantalum diaphragm), a variety of ranges to choose from, the user is convenient for debugging.
Functions of single-flange pressure transmitter
Output: 2-wire, 4~20mA DC output, digital communication, programmable set linear or square root output mode, HART protocol loaded on 4~20mA DC signal.
Power supply voltage: working condition: 10.5~42V DC
Digital communication: 16.4~42V DC
Intrinsically safe: 16.4~30V DC
Load (when output signal code is D and E): Operating status: 0 to 1335Ω Digital communication: 250 to 600Ω
HART Communication Distance: The communication distance can be up to 2Km with multi-core twisted pair cable, and the communication distance varies depending on the cable type. The formula is as follows: L=65000000/(R×C)-(C1+10000)/C
L=Length (m and ft)
R=impedance (Ω , including power supply impedance)
C = cable capacitance (pF/m or pF/ft)
C1=maximum parallel capacitance (pF/m or pF/ft)
Damping time constant of monoflange pressure transmitter: the sum of damping time constant of amplifier parts and membrane box. The constant is adjustable in the range of 0.2 to 64 seconds.
Ambient temperature: -40~85℃ (-40~185?F) -30~80℃ (-22~176?F) [with LCD meter head].
Receiving temperature: -40~120℃ (-40~248?F)
Reference accuracy of adjustable range (including linearity, hysteresis and repeatability from zero point): ±0.1 %
Stability of single-flange pressure transmitter: ± 0.1% upper limit of range / 12 months
Performance and parameters:
Output signal: 4 ~ 20MA.DC two-wire (analog)
Two-wire 4 ~ 20mA DC signal superimposed on the digital signal, selected by the user linear or open-square output. (Intelligent)
Power supply: 12~45V.DC
Range ratio: 10:1 or 100 to 1
Power supply influence: <0.005% output range/V
Load effect: No load effect when power supply is stable.
Measurement accuracy: ±0.1% of the tuning range, ±0.2 (standard accuracy is ±0.2%, if you choose other accuracy, please specify when ordering selection.)
Damping: Usually adjustable between 0.1~16 seconds, when filling inert liquid or with remote transmission device, the time constant will increase.
Start-up time: <2 seconds, no warm-up required.
Operating environment: Ambient temperature -29 to 93°C (analog amplifier)
-29~75℃ (digital/intelligent amplifier)
-29~65℃ (with display meter head)
Ambient humidity 0 to 95% (digital/smart amplifier)
Protection characteristics: Protection capability IP65
Explosion-proof type: Explosion-proof type Exd II BT4-6
Intrinsically safe type Exia II CT5
Static pressure effect: DP class zero error: for 14MPa, ±0.1% of the maximum range limit or ±0.25% of the maximum range limit (range code 3), in the pipeline pressure by zeroing to give a correction.
HP class zero error: ±0.5% of the maximum range limit, for 32MPa in the pipeline pressure by zeroing to give a correction.
Electromagnetic radiation effect: 0.05% of the maximum range value, accept radiation frequency 27 ~ 500MHz, test field strength 3V/m.
Indication table (%): LCD digital display Accuracy ±0.2
Vibration effect: any direction 200Hz vibration, ± 0.05% / g.
Installation position: diaphragm is not installed vertically, may produce less than 0.24KPa zero error, but can be corrected by zeroing.
Weight: 3.9Kg (excluding accessories)