Mainly used in food, drugs, beverages, brewing, medical equipment and other equipment for high temperature fluid/melt/gas media pressure measurement and control.
Main Technical Parameters
Range: 0~1~300MPa
Output: 2.0mV/V;4~20mA;0~5V;1~5V;0~10V
Calibration signal: 80% FS calibration; zero and full scale adjustment
Zero temperature drift: ≤±0.05%FS℃
Range temperature drift: ≤±0.05%FS℃
Limit overload: 200%FS
Response time: 5 mS (up to 90%FS)
Supply voltage: Sensor: 10VDC (6-12VDC) Transmitter: 24VDC (9-36 V)
Long-term stability: 0.1%FS/year
Insulation resistance: more than 2000MΩ 100VDC
Vibration effects: for 20HZ-1KHZ mechanical vibration, the output change is less than 0.1%FS
Signal lead-in: 5-pin connector 5pin
Thread connection: M14X1.5; M16X1.5; M18X1.5; M20X1.5; M22X1.5.
Sanitary pressure transmitter is a sanitary pressure transmitter suitable for food process measurement, its flush pressure interface can be realized through the British thread or clamp and sanitary tube, clamp and sanitary tube composition, according to the different requirements of other pressure interface for choice.SC433 pressure transmitter in the food, pharmaceutical, brewing, fermentation and other industries commonly used. Sub-conventional type, high-temperature heat dissipation type, clamp inserted into the flat membrane type, clamp oil-filled type (sanitary), clamp flat membrane type, flush membrane type, all stainless steel type.
If the medium temperature is high, you can choose the cooling transition connection. The transmitter can ****measure temperatures up to 300°C. The transmitter can also be used with a cooling transition. In addition to silicone and food-compatible oils, halogenated hydrocarbons and other filling oils are also available on request.
Features of the hygienic pressure transmitter
Low temperature sensitivity
High quality linearity
Long-term stability
Accuracy option: 0.25% FSO
Optional explosion-proof: Ex ia IIC T6
Pressure connections: G1/2 FLUSH, G1 1/2 FLUSH, etc. or various sizes of clamps.
Pressure ranges from 0 to 2KPa to 0 to 100MPa.
Silicone and food-compatible oils, halogenated hydrocarbons and other filling oils are available on request.
Output Signal/Power Supply Standard is 2-wire, 4-20 mA to 12-36 VDC.
Accuracy according to IEC60770, 0.175%FSO/0.125%FSL BFSL
Medium temperature -25~125℃, up to 300℃ when equipped with condensing unit.
Circuit/Ambient Temperature -25~85℃
Storage Temperature -40~125℃
Material: Stainless steel 1.4571(316Ti)
Housing: Stainless steel 1.4301(304)
Diaphragm: Stainless steel 1.4435(316L)
| Model CH |
|
Hygienic Pressure Transmitter |
| Measurement range | A | 0-5kPa~20KPa |
| B | 0-20kPa~70KPa | |
| C | 0-70kPa~350KPa | |
| D | 0-200kPa~700KPa | |
| E | 0-700kPa~3.5MPa | |
| F | 0-2.0MPa~7MPa | |
| G | 0-7MPa~35KPa | |
| H | 0-20MPa~100MPa | |
| Accuracy Class | Ⅰ | 0.1% |
| Ⅱ | 0.25% | |
| Ⅲ | 0.5% | |
| output signal | E | 4--20mA DC two-wire system |
| K | 1--5V DC three-wire system (telecommunications) | |
| S | intelligent | |
| M | user agreement | |
| pressure connection | R | standard type(M20×1.5) |
| P | flush membrane | |
| G | High temperature heat dissipation type | |
| K | Clamp Flat Membrane Type | |
| O | Processing according to customer's size | |
| Other options | i | intrinsically safeiaⅡCT6 |
| d | flameproofDⅡBT4 | |
| M2 | Digital LCD Indicator | |
| M3 | Digital Indicator | |
| Z | With damping adjustment | |
| Q | migration | |
| A | Adiabatic Pressure Measurement | |
| F | Negative Pressure Measurement | |
| C | Ceramic Sensors | |
| S | Radiators and process connectors | |
| Y | user agreement |