Measuring medium
|
Compatible with 316 stainless steel and a variety of liquids, gases or vapors
|
|
Measurement range
|
Gauge pressure 0 to 0.01MPa to 0 to 250MPa
|
|
overload pressure
|
2x full scale
|
|
output signal
|
4~20mA(2-wire), 0-10VDC, 0-5VDC, 1-5VDC(3-wire)
|
|
Supply Voltage
|
9~36VDC(2-wire), 24±5VDC(3-wire)
|
|
Medium temperature
|
-30~+85℃
|
|
environmental temperature
|
-20~+85℃
|
|
Storage temperature
|
-40~+90℃
|
|
relative humidity
|
0%~1 0 0%
|
|
rising time
|
Less than 5 milliseconds to 90% FS
|
|
accuracy
|
Class 1, Class 0.5, Class 0.25
|
|
Zero Adjustment
|
±8% of output range
|
|
Range Adjustment
|
±20% of output range
|
|
temperature compensation
|
≤±0.05FS/°C (temperature range: -20 to +85°C, including temperature effects on zero and range)
|
|
temperature range
|
0~70℃
|
|
stability
|
Typical: ±0.1%FS Maximum: ±0.2%FS
|
|
Media Contact Material
|
316stainless steels
|
|
Housing Material
|
304 or 316 stainless steel
|
|
Installation
|
threaded installation
|
|
pressure port
|
M20×1.5, G1/2 male thread, etc.
|
|
Lead Wire Method
|
Quad shielded cable (protection class IP68), aviation plug, DIN connector (protection class IP65)
|