Tungsten rhenium fast thermocouple |
|
Products through the company's relevant technical testing to meet factory standards. High precision, wide temperature range, low price, in line with YB4084-92 and YB/T163-1999 two rapid measurement of the temperature of the molten metal thermocouple standard. |
Technical Parameters |
Name | Model No. | Temperature range | Accuracy(℅t) | circuit resistance | electrical insulation resistance |
Tungsten rhenium 3-Tungsten rhenium 25 | KW-602 | 0-2000℃ | ≤±0.25 | <3Ω | ≥5MΩ |
Length: 500.600.850.1000mm. |
|
|
Platinum Rhodium Fast Thermocouple |
|
Platinum rhodium fast temperature measurement thermocouples, with hard technology and stable and excellent quality, are not only widely used in major domestic steel mills, but also exported to a large number of European countries every year. |
I. Citation standards 1. Product standard: YB/T163-1999 (consumable rapid measurement of metal melt temperature with thermocouple). 2. Couple wire standard: S type: GB/T3772-98 R type: GB/T1598-98 B type: GB/T2902-98 3. Compensation wire standard: GB/T4989-94 (S type. R type thermocouple compensation wire)
|
II. Product name model and technical parameters: |
Name | index number | Model No. | Upper temperature limit | allowances | circuit resistance |
Platinum rhodium 10-platinum | S | KS—602 | 1650℃ | ≤±5℃ | <3Ω |
Platinum rhodium 13-platinum | R | KR—602 | 1650℃ | ≤±5℃ | <3Ω |
Platinum rhodium 30 - Platinum rhodium 6 | B | KB—602 | 1800℃ | ≤±5℃ | <3Ω |
III. Product length: Coupling head: 500, 600, 850, 1000m.
|
|
|
Rapid Thermocouple Guns and Tips |
|
Temperature measurement in the gun head plug core positive. The extremely negative leads are compensated, i.e. made of the corresponding compensating wire material, so they are divided into SC (RC) type, BC type and WC3/25 type. They are used for Pt rhodium 10-platinum (Pt rhodium 13-platinum), Pt rhodium 30-platinum rhodium 6 and tungsten rhenium 3-tungsten rhenium 25 rapid thermocouples. The outer diameter of the lance is Φ16 mm (special sizes on request) and the length is 1 m - 4.5 m. The lance is available in a wide range of sizes and lengths. |
|
|
Thermocouple Compensation Leads |
|
Compensation wire standard implementation: GB/T4989-94 (S. R type thermocouple)
JB/T9496-99 (WRe3/25 thermocouple) (WRe5/26 thermocouple)
|