1. Product Usage: This product is suitable for power lines with a rated voltage (U0/U) of 3.6/6 to 26/35KV, for the purpose of power transmission and distribution.
2. Product standard: GB12706-91 rated voltage 35KV and below copper core, aluminum core plastic insulated power cables.
3. Product usage characteristics: (1) When laying cables in environments with temperatures not lower than 0 ℃, there is no need for pre heating. The laying height of cables is not limited. (2) The long-term allowable working temperature of the cable core shall not exceed the following regulations: for cables with an outer protective layer of polyvinyl chloride sheath, the temperature shall be 90 ℃; The outer protective layer of the cable is made of polyethylene sheath, and the temperature is 80 ℃. (3) When the wire core is short circuited (for a maximum of 5 seconds), the temperature shall not exceed 250 ℃. (4) The minimum bending radius for cable laying is specified as follows: single core cable: 20 (d+D) ± 5%; Three core cable: 15 (d+D) ± 5%. In the formula: D is the actual outer diameter of the cable, and d is the actual outer diameter of the conductor.
4. Product model, name, and scope of use
| model | Name | Scope of use | |
| Copper core | Aluminum core | ||
| YJV | YJLV |
Cross linked polyethylene insulated polyvinyl chloride sheathed power cable |
Fixed installation in the air, indoors, cable trenches, tunnels, or underground |
| YJY | JYLY |
Cross linked polyethylene insulated polyethylene sheathed power cable |
Fixed installation indoors, in cable trenches, tunnels, or underground |
| YJV22 | YJLV22 | Cross linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable | Fixed installation in places with external pressure |
| YJV23 | YJLV23 | Cross linked polyethylene insulated steel tape armored polyethylene sheathed power cable | Fixed installation in places where external forces are often applied |
| YJV32 | YJLV32 | Cross linked polyethylene insulated fine steel wire armored polyvinyl chloride sheathed power cable | Fixed installation in places that require the ability to withstand tensile forces |
| YJV33 | YJLV33 | Cross linked polyethylene insulated fine steel wire armored polyethylene sheathed power cable |
Fixed installation in places that require the ability to withstand tensile forces |
| YJV42 | JYLV42 | Cross linked polyethylene insulated thick steel wire armored polyvinyl chloride sheathed power cable | Fixed installation underwater, in vertical shafts, or in places where tensile strength is required |
| YJV43 | YJLV43 |
Cross linked polyethylene insulated thick steel wire armored polyethylene sheathed power cable |
Fixed installation in places that require the ability to withstand high tensile forces |
Note: One or two single core cables are not allowed to be laid in iron pipes.