Direct mount pressure transmitter, can be installed directly in the pipeline, a variety of thread options, accurate measurement, online adjustment, easy to operate, diffusion silicon, capacitance sensor, stable performance. Tens of thousands of fatigue tests, strict temperature compensation, HART/PA/FF multiple protocol options. Optional stainless steel shell, suitable for corrosive environments.
Application Sectors
Oil, gas, chemical, urban construction, electric power, medicine, metallurgy, light textile
Technical indicators
Measuring medium: liquid, gas or vapor
Power supply: 24V DC (normal operating voltage range: 10.5 ~ 40V DC)
Output signal: 2-wire, 4-20mA DC output, superimposed HART protocol digital communication.
Measurement range:
Range Code Range (KPa) Measuring Range
3 0.8~7.5KPa -7.5~7.5KPa
4 1.0~37.4KPa -37.4~37.4KPa
5 4.7~186.8KPa -100~186.8KPa
6 17.3~690Kpa -100~690KPa
7 51.7~2068KPa -100~2068KPa
8 172.3~6890KPa 0~6890KPa
9 689~20680KPa 0~20680KPa
0 1723~68900KPa 0~68900KPa
Load Characteristics:
Explosion-proof marking:Flame-proof type Exd IICT6, Intrinsically safe type Exia IICT6
Protection class:IP66
Migration characteristics
1、Positive maximum mobility is 500% of the minimum calibration range.
2、Maximum negative migration rate is 600% of the minimum calibration range.
Ambient temperature:
-40~85℃ (-30~70℃ for LCD head)
Flame-proof type: -30~70°C
Intrinsically safe type: -30~60°C
Liquid connection temperature: -40~105℃
Storage temperature:-40~85℃
Ambient humidity: 0~100%RH
Static pressure and overpressure limit: withstand pressure range: 100KPa ~ 40MPa
Flanges on both sides can withstand pressure: 60Mpa
Volume change: less than 0.16cm3
Damping: 0.1~32.0s (adjustable)
Starting time: 2s