Direct Mount Pressure Transmitter

product details

Direct mount pressure transmitter, can be installed directly in the pipeline, a variety of thread options, accurate measurement, online adjustment, easy to operate, diffusion silicon, capacitance sensor, stable performance. Tens of thousands of fatigue tests, strict temperature compensation, HART/PA/FF multiple protocol options. Optional stainless steel shell, suitable for corrosive environments.


Application Sectors

Oil, gas, chemical, urban construction, electric power, medicine, metallurgy, light textile


Technical indicators

Measuring medium: liquid, gas or vapor

Power supply: 24V DC (normal operating voltage range: 10.5 ~ 40V DC)

Output signal: 2-wire, 4-20mA DC output, superimposed HART protocol digital communication.



Measurement range:

Range Code Range (KPa) Measuring Range

3 0.8~7.5KPa -7.5~7.5KPa

4 1.0~37.4KPa -37.4~37.4KPa

5 4.7~186.8KPa -100~186.8KPa

6 17.3~690Kpa -100~690KPa

7 51.7~2068KPa -100~2068KPa

8 172.3~6890KPa 0~6890KPa

9 689~20680KPa 0~20680KPa

0 1723~68900KPa 0~68900KPa

Load Characteristics:


Explosion-proof marking:Flame-proof type Exd IICT6, Intrinsically safe type Exia IICT6


Protection class:IP66


Migration characteristics


1、Positive maximum mobility is 500% of the minimum calibration range.


2、Maximum negative migration rate is 600% of the minimum calibration range.


Ambient temperature:


-40~85℃ (-30~70℃ for LCD head)


Flame-proof type: -30~70°C


Intrinsically safe type: -30~60°C


Liquid connection temperature: -40~105℃


Storage temperature:-40~85℃


Ambient humidity: 0~100%RH


Static pressure and overpressure limit: withstand pressure range: 100KPa ~ 40MPa


Flanges on both sides can withstand pressure: 60Mpa


Volume change: less than 0.16cm3


Damping: 0.1~32.0s (adjustable)


Starting time: 2s