Welcome to Anhui Gaosheng Electric Group Co., Ltd.!
15212195160(Manager)
Enter product keywords

Fluoroplastic insulated high temperature resistant control cable

product details

Fluoroplastic insulated high temperature resistant control cable

1: Product Features and Applications

This product is suitable for fixed installation of transmission and distribution lines, power transmission or motor lead wires with AC rated voltage of 450/750v and below. It has the characteristics of high temperature resistance, corrosion resistance, acid and alkali resistance, corrosive gas resistance, waterproofing, etc. It has stable electrical performance in high temperature environments, large current carrying capacity, long service life, and is widely used in metallurgy, power, petrochemical, large construction, automobile manufacturing and other industries.

2: Product execution standards

  Q/GS09-2015

The flame retardant and fire-resistant characteristics test shall comply with GB12666-90 standard

3: Usage characteristics

1. Rated AC voltage: U0/U  450/750v

2. Maximum operating temperature:

Fluorine F4 insulation does not exceed 125 ℃

Perfluoroethylene propylene (F46) insulation not exceeding 200 ℃

Soluble polytetrafluoroethylene (PFA) insulation not exceeding 260 ℃

Shielding options include: P copper wire, P1 tin plated, P2 copper tape, P3 aluminum foil PP2

Armor: 22 steel strip armor, 32 thin steel wire armor

3. Minimum ambient temperature: Fluoroplastic insulation and sheath

Fixed installation -40 ℃, non fixed installation -15 ℃

4. The temperature for cable installation and laying should not be lower than 0 ℃ (for fluoroplastic, silicone rubber, and nitrile sheathed cables, it should not be lower than -25 ℃).

5. Allowable bending radius for cables: The minimum allowable bending radius for single core cables is 15 times the outer diameter of the cable

The minimum requirement for multi-core cables is 10 times the outer diameter of the cable




Model
product name
Normal operating temperature ℃
KFF46
Fluoroplastic insulated and sheathed control cables
-60-200
KFF46-22
Fluoroplastic insulated and sheathed steel tape armored control cable
-60-200
KFF46P
Fluoroplastic insulated and sheathed copper braided shielded control cable
-60-200
ZR-KF46(FV)
Fluoroplastic insulated flame-retardant polyvinyl chloride sheathed control cable
-40-105
ZR-KF46-22(FV22)
Fluoroplastic insulated steel tape armored flame-retardant polyvinyl chloride sheathed control cable
-40-105
ZR192-KFF46
PFA insulated and sheathed control cable (imported raw materials)
-60-260
ZR192-KFF46P
PFA insulated and sheathed copper braided shielded control cable (imported raw material)
-60-260
ZR192-KFF46-22
PFA insulated and sheathed steel tape armored control cable (imported raw materials)
-60-260
YGC-KF46(FG)
Fluoroplastic insulated silicone rubber sheathed control cable
-60-180
YGC-KF46-22(FG22)
Fluoroplastic insulated steel tape armored silicone rubber sheathed control cable
-60-180
YVF-KF46
Fluoroplastic insulated flame-retardant nitrile polyvinyl chloride sheathed control cable
-60-105
YVF-KF46-22
Fluoroplastic insulated steel tape armored flame-retardant nitrile polyvinyl chloride sheathed control cable
-60-105

Note: Add R to the prototype number for soft structure cables, and tin plated copper wires can be used in the conductor core.

5: Code name and meaning



Code
Meaning of code
Series code
K control
F(F46)
Perfluoroethylene propylene (F46)
YVF
Nitrile rubber
G
silicon rubber
192
Imported PFA insulation and sheath
ZR(V)
Flame retardant polyvinyl chloride (divided into three types: flame retardant at 70 ℃, 90 ℃, and 105 ℃)
22
Steel belt armor
32
Thin steel wire armor, 42 thick steel wire armor
P
Copper braided shielding, P2 copper tape shielding, P3 aluminum foil shielding
R stranded conductor

Note: Our company can develop customized production of various types and specifications of cables according to customer on-site requirements.

Contact phone number: Manager Chen 18355080606 (same WeChat account)








Note: Our company can develop customized production of various types and specifications of cables according to customer on-site requirements.

Contact phone number: Manager Chen 18355080606 (same WeChat account)








product details

Filling in your phone and email information will help us to contact you in a timely manner and solve the problem you raised as soon as possible.

project case
gaosheng electrical