Product name: Single-phase parallel constant power electric heating belt
Model: GS-RBPFF
Product specifications: 3-8mm
Temperature range: 0-150℃
Temperature resistance: 205℃
Standard power: 10-40W/M, customizable
Common voltage: 12V 24 36 110 220V
Product certification: CE Ex ISO9001
1. Product Structure and Working Principle
The power busbar is two parallel insulated copper wires, the electric heating wire is wound on the inner insulating layer, and the electric heating wire is connected to the busbar at certain distances (that is, the “heating section length”) to form a continuous parallel resistance.After the busbar is energized, each parallel resistor generates heat, thus forming a continuous heating cable.
Single-phase constant-power heating cables are mainly used for antifreeze and thermal insulation of pipelines and instruments everywhere, with a maximum maintenance temperature of 150℃, and can be used for explosive gas occasions in the first and second zones of the factory.
2. Product specifications and main technical characteristics
Maximum fluid maintenance temperature: Refers to the maximum process temperature that the medium in the pipeline needs to maintain, and generally should not exceed the value specified in this table.
Rated voltage: 220V
High temperature resistance: 250℃
Normal insulation resistance: ≥ 20 megohms
Protection level: IP54
Dielectric strength: 2000V 50Hz/1min
Explosion proof certificate number: CJE × 07.125U
Insulation layer material: F46 fluoroplastic
Size (including textile and outer sheath): 6.3 × 9.5m